Description
FEATURES:
Pure sine wave solar inverter(on/off Grid)
Output power factor 1.0
WIFI&GPRS available forlOS and Android
Inverter can run without battery
One-key restoration to factory Settings
Built-in Lithium battery automatic activation
Built-in 120AMPPT Solar charge:max 4200W(for 3.6KW),max 6000W(for 6.2KW)
AC output voltage 120VAC
High PV input voltage range(60~500VDC)
Built-in anti-dust kit for harsh environment
Smart battery charge design to optimize battery life
Dual output

PRODUCT DATA SHEET:
|
MODEL
|
ECO-LV-3.6KWPLUS
|
ECO-LV-6.2KW PLUS
|
|
Phase
|
1-phase
|
|
|
Maximum PV Input Power
|
4200W
|
6000W
|
|
Rated Output Power
|
3600W/3600VA(3000/3150/3300)
|
6200W/6200VA(5300/5500/5700)
|
|
Maximum Solar Charging Current
|
120A
|
100A
|
|
GRID-TIE OPERATION
|
||
|
PV INPUT (DC)
|
||
|
Nominal DC Voltage/Maximum DC Voltage
|
360/500VDC
|
|
|
Start-up Voltage /Initial Feeding Voltage
|
60VDC/90VDC
|
|
|
MPPT Voltage Range
|
60~450VDC
|
|
|
Maximum Input Current
|
1/18A
|
1/22A
|
|
GRID OUTPUT(AC)
|
||
|
Nominal Output Voltage
|
120VAC(100/105/115V settable)
|
|
|
Output Voltage Range
|
90-150VDC
|
|
|
Nominal Output Current
|
30A
|
51.5A
|
|
Power Factor
|
>0.99
|
|
|
EFFICIENCY
|
||
|
Maximum Conversion E ciency(DC/AO
|
98%
|
|
|
TWO LOAD OUTPUTPOWER
|
||
|
Full Load
|
3600W
|
6200W
|
|
Maxium Main Load
|
3600W
|
6200W
|
|
Maxium Second Load(battery mode)
|
1200W
|
2067W
|
|
Maxium I oad Cut off Voltag
|
26VDC
|
52VDC
|
|
Maxium Load Return Voltage
|
27VDC
|
54VDC
|
|
OFF-GRID OPERATION
|
||
|
AC INPUT
|
||
|
AC Start-up Voltage /Auto Restart Voltage
|
110VAC/120VAC
|
|
|
Acceptable Input Voltage Range
|
90~145AC±2%
|
|
|
Frequency Range
|
49~51±1HZ
|
|
|
Maximum AC Input Current
|
40A
|
80A
|
|
PV INPUT(DC)
|
||
|
Nominal DC Voltage/Maximum DC Voltage
|
360/500VDC
|
|
|
MPPT Voltage Rang
|
60~450VDC
|
|
|
Maximum Input Current
|
1/18A
|
1/22A
|
|
BATTERY MODE OUTPUT(AC)
|
||
|
Nominal Output Voltag
|
120VAC(100/105/115V settable)
|
|
|
Output Waveform
|
Pure sine wave
|
|
|
E dency (DCtoAO)
|
94%
|
|
|
BATTERY&CHARGER
|
||
|
Nominal DC Voltage
|
24VDC
|
48VDC
|
|
Maximum Solar Charging Current
|
120A
|
120A
|
|
Maximum AC Charging Current
|
100A
|
100A
|
|
Maximum Solar+AC Charging Current
|
120A
|
120A
|
|
HYBRID OPERATION
|
||
|
PV INPUT(DC)
|
||
|
Nominal DC Voltage/Maximum DC Voltage
|
360/500VD
|
|
|
Start-up Voltage /lhitial Feeding Voltage
|
90VDC/120VDC
|
|
|
MPPT Voltage Range
|
60~450VDC
|
|
|
Maximum Input Current
|
1/18A
|
1/22A
|
|
GRID OUTPUT(AC)
|
||
|
Nominal Output Voltage
|
120VAC(100/105/115V settable)
|
|
|
Output Voltage Range
|
60-450VDC
|
|
|
Nominal Output Current
|
30A
|
51.6A
|
|
AC INPUT
|
||
|
AC Start-up Voltage /Auto Restart Voltage
|
120-140VAC/180VAC
|
|
|
Acceptable Input Voltage Range
|
90-280VAC or 170-280VAC
|
|
|
Maximum AC Input Current
|
40A
|
80A
|
|
Maximum Charging Current
|
120A
|
100A
|
|
GENERAL
|
||
|
PHYSICAL
|
||
|
Dimension,DxWxH(mm)
|
420*350*110
|
|
|
Carton Dimension,DXWXH(mm)
|
500*415*180
|
|
|
Net Weight(kgs)
|
8.8
|
9.5
|
|
Gross Weight(kgs)
|
10
|
11.5
|
|
INTERACE
|
||
|
Communication Port
|
RS232/RS485/WIFI/GPRS/LITHIUM BATTERY
|
|
|
ENVIRONMENT
|
||
|
Humidity
|
5%to 95%Relative Humidity(Non~condensing)
|
|
|
Operating Temperature
|
-10℃~50 C
|
|
|
STANDARD
|
||
|
Compliance Safety
|
CE
|
|